Mestra M-9 Polymerizer, Curing for Flasks
$2,432.00
SKU
MES 080400
Made completely of stainless steel
Polymerizes 9 flasks with clamp 030390
Polymerizes 9 flasks with clamp 030390
Made completely of stainless steel. Polymerizes 9 flasks with clamp 030390
The M-9 polymerizer is equipped with a processor to change temperature according to a pre-set program.
On the M-9 the operator (user) can select the following:
a) A delayed start time set in hours and minutes from 0.00 to 99 hours 59 minutes. This means the program can be pre-set to start at a specific time. The delay works every time the program is initiated.
b) The duration of each temperature increases gradient in hours and minutes from 0.00 to 99 hours 59 minutes.
c) The desired holding time in hours and minutes from 0.00 to 99 hours 59 minutes at each plateau.
END OF TREATMENT WARNING BUZZER
– When the program completes treatment or A4, a modulated warning buzzer is set off for one minute. When the alarm buzzer sounds, press any key to acknowledge the alarm and continue the program.
– If the power fails the regulator stores all its data, and when power returns it continues from the same point in the program.
– Programs and parameters are stored indefinitely when power to the regulator is cut off.
Standard UL 61010C-1
TECHNICAL CHARACTERISTICS
OUTSIDE DIMENSIONS:
Height (with handle): 480 mm
Width (with drop): 270 mm
Length: 480 mm
Weight: 15 kg / 34 lbs.
Supply voltage: 115V, 60 Hz
Rated power: 1750 W
INSIDE DIMENSIONS:
Height: 335 mm
Width: 180 mm
Length: 350 mm
The M-9 polymerizer is equipped with a processor to change temperature according to a pre-set program.
On the M-9 the operator (user) can select the following:
a) A delayed start time set in hours and minutes from 0.00 to 99 hours 59 minutes. This means the program can be pre-set to start at a specific time. The delay works every time the program is initiated.
b) The duration of each temperature increases gradient in hours and minutes from 0.00 to 99 hours 59 minutes.
c) The desired holding time in hours and minutes from 0.00 to 99 hours 59 minutes at each plateau.
END OF TREATMENT WARNING BUZZER
– When the program completes treatment or A4, a modulated warning buzzer is set off for one minute. When the alarm buzzer sounds, press any key to acknowledge the alarm and continue the program.
– If the power fails the regulator stores all its data, and when power returns it continues from the same point in the program.
– Programs and parameters are stored indefinitely when power to the regulator is cut off.
Standard UL 61010C-1
TECHNICAL CHARACTERISTICS
OUTSIDE DIMENSIONS:
Height (with handle): 480 mm
Width (with drop): 270 mm
Length: 480 mm
Weight: 15 kg / 34 lbs.
Supply voltage: 115V, 60 Hz
Rated power: 1750 W
INSIDE DIMENSIONS:
Height: 335 mm